Post Offer Free
Shanghai Shenghua Cable (Group) Co., Ltd.  

Gold Index: 9652

You are here: home  > Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System

Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: ABC-ACSR/XLPE 0.6/1KV

Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System
 
Description</stron

Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System

 

Description

 

The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.

 

Construction

 

  1. Conductor:

 

a) Phase - The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.

 

b) Neutral or messenger - The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded.

 

  1. Insulation:

 

The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.

 

 

 

 

 

 

1 Phase conductor + 1 Messenger conductor

 

 

 

 

 

 

 

Schedule of technical particulars

 

bigPhoto
 Mr. Ms. Mayling Zhao

Tel: 86-21-68172999
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Shanghai Shenghua Cable (Group) Co., Ltd. [China (Mainland)]


Business Type:Manufacturer
City: Shanghai
Province/State: Shanghai
Country/Region: China (Mainland)

You May Like:

Product (197)

Phase conductor                      
Nominal cross-sectional area mm² 16 16 25 35 50 70 95 120 150 185
Number of cores   1 3 3 3 3 3 3 3 3 3
Minimum number of wires   6 6 6 6 6 12 15 15 30 30
Nominal insulation thickness mm 1 1 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0
Diameter of insulated core mm 6.8 6.8 8.5 9.5 11.2 13.0 15.1 16.6 18.4 20.6
Max. DC resistance at 20 ohm/km 1.91 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164
Current rating at still wind, ambient A 61 61 84 104 129 167 209 246 283 332
temperature=30
Conductor temperature=75                      
Messenger conductor                      
Nominal cross-sectional area mm² 25 25 25 25 35 50 70 70 95 120
Minimum number of wires   6 6 6 6 6 6 12 12 15 15
Nominal insulation thickness mm 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.6 1.6
Diameter of insulated core mm 8.5 8.5 8.5 8.5 9.5 11.2 13.1 13.1 15.1 16.6
Max. DC resistance at 20 ohm/km 1.312 1.312 1.312 1.312 0.943 0.693 0.469 0.469 0.349 0.273
Calculated breaking load kN 6.4 6.4 6.4 6.4 8.9 12.1 18.0 18.0 24.2 30.8
Completed cable